Pramc-7211 software installation – Artesyn PrAMC-7211 PNE3.0 Software Installation Guide (June 2014) User Manual
Page 23

PrAMC-7211 Software Installation
PrAMC-7211-PNE3.0 Software Installation Guide (6806800L07B)
23
From
TIMEOUT 50
DEFAULT kernel initrd=minrootfs.cpio.gz rdinit=/linuxrc
console=ttyS0,9600n8 INTF=front
TFTPSERVER=192.168.2.20:/PrAMC721x-WR-3.0-BBS-RM01-PrePINV
DHTMOUT=6 TIMEOUT=16
To
TIMEOUT 50
DEFAULT kernel initrd=minrootfs.cpio.gz rdinit=/linuxrc
console=ttyS0,9600n8 INTF=front
TFTPSERVER=192.168.2.20:/PrAMC721x-WR-3.0-BBS-RM01-1.0.2/disk
DHTMOUT=6 TIMEOUT=16
6. Change BIOS boot configuration to netboot as described in
.
After BIOS settings are changed and saved, the blade reboots and image is picked up
automatically.
7. After reset, the board starts booting with the kernel from new load. The new kernel runs
the installation linuxrc script.
8. The installation is automatic and output is as given below. After installation is over, the
system reboots. On system reboot after installation, change boot configuration to disk-
boot as described in
Changing BIOS Setting Boot Option to Disk Boot
******************************************************************
*************************** Installation Ramdisk *****************
******************************************************************
******************************************************************
Checking for necessary commands...
basename...............[ exists ]
bash...............[ exists ]
cat...............[ exists ]