Media Calibration
After the media is loaded, please perform media calibration to
calibrate the label sensor in advance.
1. Turn off the printer
2. Press and hold the PAUSE button and turn on the power.
3. When
“CALIBRATION …” is displayed on the LCD, and
both READY and MEDIA indicators blink, release the
PAUSE button.
(The Ethernet models will first
prompt “ETHERNET CARD
INITIALIZING” on LCD after Power-on and then show the
“CALIBRATION …” message as described above.)
4. The printer feeds 12-inches of blank labels.
5.
When “READY” is displayed, the READY and MEDIA
indicators stop blinking but remain illuminated.
Note: For X-1000VL, the steps about LCD can be ignored.
Important!
1. I
t’s suggested to perform media calibration after changing
media types.
2. Before calibration, be sure media and ribbon (for thermal
transfer printing) have been loaded correctly. The label sensor
needs to locate properly to index labels’ gaps/ notches/ holes.