Printer lcd function settings and parameters – Argox X Series User Manual
Page 40
40
Printer LCD function settings and parameters:
Item
Range
Factory
Default
Remarks
PRINT MODE
DIRECT
THERMAL/
THERM.
TRANSFER
THERM.
TRANSFER
AUTO-CAL.
MODE
MODE 1
MODE 2
MODE 3
MODE 4
MODE 1
Mode 1: Printer
performs Auto
Calibration after
printing the first label,
if label height differs
from parameters in
printer's flash.
Mode 2: Printer
performs Auto
calibration when print
head is closed.
Mode 3: Printer finds
the first label gap
when print head is
closed.
Mode 4: Mode 1/2/3
all disabled. Manual
calibration is needed.
Not for X-2000V.
CONTROL
CODE SET
STANDARD
ALTERNATIVE
STANDARD
Available only in
PPLA printer
language.