20

Thermostat Application Module (not provided in the kit) is an example of
an application-specific module that demonstrates an HVAC control sys-
tem. Implementing an application module with the Application Module
Interface requires that the eZ80F91 Module also be mounted on the
eZ80Acclaim! Development Kit, because the eZ80F91 device controls the
application. To mount an application module, use the two male headers J6
and J8.

Connector J6 carries the General-Purpose Input/Output ports (GPIO), and
connector J8 carries memory and control signals. To design an application
module, you must be familiar with the architecture and features of the
eZ80F91 Module currently installed.

Table 6

and

Table 7

list the signals

and functions related to each of these connectors by pin. Power and
ground signals are omitted for the sake of simplicity.

Table 6. GPIO Connector J6*

Signal

Pin #

Function

Direction

Notes

SCL

5

I

2

C Clock

IN/OUT

SDA

7

I

2

C Data

IN/OUT

MOD_DIS

9

Modem Disable

IN

If a shunt is installed between
pins 6 and 9, the modem
function on the eZ80Acclaim!

®

Development Kit is disabled.

MWAIT

13

WAIT signal for
the CPU

IN

EM_D0

15

Emulated, Bit 0

IN/OUT

CS3

17

Chip Select 3 of
the CPU

OUT

This signal is also present on
the J8.

EM_D[7:1]

21,23,25,
27,29,31,
33

Emulated, Bit
[7:1]

IN/OUT

Reserved

35