Zilog Z8F1621 User Manual
Page 7

In-Circuit Emulator
User Manual
UM016804-0208
4
Figure 2. Z8 Encore! XP
®
F64xx Series ICE Rear Panel
4. Connect the ribbon cables from the target POD to connectors J2 and
J10 on the Z8 Encore! XP
®
F64xx Series ICE. (See
Figure 3
and
Figure 4
.)
5. Plug the target POD into the package adapter installed on the target
board.
6. Connect a 5 VDC power supply to the Z8 Encore! XP
®
F64xx Series
ICE. The ICE Run LED should illuminate (see
Figure 5
). If either
power LED fails to illuminate, or if the ICE Fail LED either blinks
continuously or fails to extinguish after 15 seconds, there is a problem
with the unit. Contact Zilog support at
http://www.zilog.com/
for a replacement unit.
7. Connect a 5 VDC power supply to the Z8 Encore! development
board.
DB9 connector
Link
LAN
Ethernet
(RJ-45)
USB
(unused)
Reset
Switch
3.3 VDC OK
1.8 VDC Ok
Ext
Pwr
In