Magnetic buzzer, Reset circuit – Zilog S3F8S19 User Manual
Page 17
UM026801-0914
Magnetic Buzzer
S3F8S19 Development Kit
User Manual
14
•
Low-voltage check to reset system
•
ISP-related option selectable (ROM address 3EH) via Smart Option
•
Oscillator selection, LVR selection (ROM address 3FH) via Smart Option
To learn more about the S3
.
Magnetic Buzzer
The CEM1206S magnetic buzzer (U2) manufactured by CUI Inc. is rated at a frequency
of 2400 Hz and an operating voltage of 3.0
–
8.0 V zero-to-peak (V
0–P
). An image of the
CEM1206S device is shown in Figure 14.
This buzzer is activated by setting the jumper J9 to the 1-2 position that connects the
buzzer to the P3.0 pin of the S3F8S19 MCU in the Development Kit.
To learn more about the CEM1206S device, vi
Reset Circuit
The reset circuit features a 100 KΩ
pull-up resistor R6 and SW1. This circuit resets the
S3F8S19 MCU when SW1 is pressed. See Figure 15 for a representation of the reset cir-
cuit.
Figure 14. Magnetic Buzzer