Parts placement – Vectronics VEC-1320K User Manual
Page 10
VEC-1320K/1330K/1340K/1380K Owner's
Manual
8
! 3
330 pF multilayer (331)
C14,C27,C28
220-0330
! 1
470 pF multilayer (471)
C23
220-0470
! 1
680 pF multilayer (681)
C24
220-0680
! 2
2.2 uH choke (red-red-gold)
L2,L3
401-3220
! 1
3.3 uH choke (orange-orange-gold)
L1
401-3330
! 1
10.108 MHz crystal
Y1
410-10800
VEC-1340K 40-Meter Parts Package:
# Qty
Part Description
Designation
VEC P/N
! 1
3.3 pF ceramic disc (3.3)
C13
200-00033-1
! 2
47 pF multilayer (47 or 470)
C2,C15
220-0047
! 2
100 pF multilayer (101)
C18,C25
220-0100
! 1
270 pF multilayer (221)
C14
220-0270
! 1
330 pF multilayer (331)
C23
220-0330
! 2
470 pF multilayer (471)
C27,C28
220-0470
! 1
1000 pF multilayer (1000)
C24
220-1010
! 3
4.7 uH choke (yellow-violet-gold)
L1,L2,L3
401-3470
! 1
7.040 MHz crystal
Y1
405-04000
! 1
24" length of #24 wire
870-3024G
VEC-1380K 80-Meter Parts Package:
# Qty
Part Description
Designation
VEC P/N
! 1
4.7 pF ceramic disc (4.7)
C13
200-00047-1
! 1
68 pF multilayer (68 or 680)
C15
220-0068
! 1
100 pF multilayer (101)
C18
220-0100
! 1
180 pF multilayer (181)
C2
220-0180
! 2
470 pF multilayer (471)
C23,C25
220-0470
! 4
820 pF multilayer (821)
C14,C24,C27,C28
220-0820
! 3
10 uH choke (brown-black-black)
L1,L2,L3
401-4100
! 1
3.5795 MHz crystal
Y1
405-0107
! 1
24" length of #24 wire
870-3024G
Once again, if any parts are missing, consult the warranty page on the inside
cover for specific replacement instructions. If your parts inventory is complete,
you're ready to start building. Remember, once construction begins, you may no
longer return your kit.
Many builders find it helpful to make a Xerox copy of the parts-placement
diagram and the schematic diagram . These may then be posted in your work
area for reference. A parts-placement layout is also printed on the circuit board
to help you locate where to install each part.
PARTS PLACEMENT