To recall a Scene:

1. Turn the knob to scroll through Scenes, which display in alphanumeric order.

A Scene name blinks if it has not been recalled.

2. Press the knob to recall that Scene.

The Scene name stops blinking.

To save the current Scene:

1. Navigate to the Save button.

2. Press ENTER to update the Scene with the current state of the unit.

The Save button is inactive if the Scene has not been edited.

To create a new Scene:

1. Navigate to the New button.

2. Press ENTER to create a new Scene with the current state of the unit.

An automatically generated number is assigned.

To restore all parameters in the unit except the MADI and network configurations,
and the unit name, recall Scene 0.

NOTE:

After editing Scene 0, the

Save

button will be inactive. Use

New

to save the current

state of the unit.

See Chapter 5: Dugan Control Panel Software to learn how to name and otherwise
manage Scenes.

TIP:

To eliminate an unwanted noise in the mix, use the gain displays to locate the offending
channel, then activate its

mute

button.