Dugan Model M User Guide

38

The Master indicators are:

online:

lights when a unit is connected to the Dugan Control Panel

MADI-ADAT, norm-slave:

show their rear panel switch settings

MADI:

indicates a valid MADI source

clock lock:

indicates a valid Word Clock source

The Master controls, located on the far right, include reset, meters, system, OVERRIDE,
PRESET

, and MUTE. A set of OVERRIDE, PRESET, and MUTE buttons appears for each ac-

tive group. Each control is discussed below.

Reset

We recommend clicking reset before making a new setup, which sets all operating
parameters to default values. This does not include setup parameters such as network
and MADI configuration or the unit’s name.

Meters

The meters have three display modes. The default mode is auto mix gain, which is the
most useful display during normal operation. The input and output meters are only
used when setting or checking levels.

Table 5-2 Meter modes

Click on the Master meters button to cycle through the three meter display modes.

Clock Source

The clock source button displays the currently assigned source. If Word Clock and any
other clock source is present, the Dugan automatically selects Word Clock.

Click on clock source to override the automatically assigned clock source to select
your own. Clock sources are MADI, ADAT, Word Clock, and internal (48 kHz).

NOTE:

All mute LEDs flash together if there is no valid clock source. This typically means the
unit has no digital signal at the inputs.

Meter Displays

Meter Color

auto mix gain

action of the Dugan Speech System

green

input

input level

yellow

output

output level

blue