beautypg.com

Troubleshooting guide, Heating system, Electrical system – Dimension One Spas Aquatic Fitness System User Manual

Page 28: Water system

background image

Dimension One Spas - Aquatic Fitness System - Owner’s Manual

26

Troubleshooting Guide

Heating System

Symptom

Problem

Corrective Action

1.

Temperature setting is too low

1.

Turn up the thermostat

2.

Dirty filter

2.

Clean filter

Does not heat

3.

Flow switch out of adjustment

3.

Call for service

1.

Temperature setting is to high

1.

Turn down the thermostat

Too hot

2.

High limit tripped

2.

Call for service

Flashing temperature of 34

°F or

134

°F appears on the display

Possible temperature sensor failure

Call for service

Electrical System

Symptom

Problem

Corrective Action

Will not turn on – in any mode

No power

Check circuit breaker and/or GFCI

Turns on by itself

Normal automatic daily power filtration,
or anti-freeze cycle

No action required

Light will not turn on

Burned out bulb

Replace bulb

1.

Automatic timer has shut pump off

1.

Push JETS button to start another

cycle. If desired reprogram
automatic pump timer for a longer
duration.

Pump shuts down unexpectedly while
in use

2.

Motor over-heated and automatic

protective device has shut down
pump(s)

2.

If pump(s) will not restart when

JETS pad is pushed, call for
service

1.

Check water level

2. Clean

filter

If problem persists:

1. Turn

off

power

2.

Restart the system

If problem persists:

3 flashing lights appear on the Control
Panel

Possible sensor errors

Call for service

Water System

Symptom

Problem

Corrective Action

Pulsating jets

Water level too low

Fill with water to approximately 6 inches
below the top edge of the pool/spa

1.

HydroTherapy Jets closed

1. Open

Jets

2.

Diverter Valve turned

2.

Turn the Diverter Valve clockwise

or counter clockwise

3. Dirty

Filter

3. Clean

Filter

4.

Air lock

4.

Loosen pump union to allow air to

escape

No Jet Action, or action is poor

5.

Gate valve closed

5.

Open gate valve

1. Check

TA/pH

2.

Test and adjust

The water is cloudy or has a smell

The water has a chemical imbalance or
lack of filtration.

3.

Change Water if necessary