beautypg.com

CIRCUTOR AR5L Series User Manual

Page 37

background image

37

6.1.2.3.- NAME: recording file name

File name setting (8 characters, with no extension) and file type setting

(Cyclical – Linear).

File name.

NAME

STD-PROG

- Pressing [ENTER]: Text on display is directly validated.

- To modify: (alphanumeric input).

- Select with keys [

6

6

6

6], [5

5

5

5], [8

8

8

8] or [3

3

3

3] the character to modify and press

[SET] to validate each character.

- Select “

“ on display + [SET] to delete a character.

- [ENTER] to validate the total text or [ESC] to exit with no modification.

NOTES!

a) If the typed name already exists in memory, when exiting setting actions, the

display will show:

“Overwrite file Sure? “ --> Do you really overwrite the file?

- If yes is answered, the previous file is deleted.

- If no is answered, setup menu is not exited, thus a new name can

be typed for the file, or the setting actions can be cancelled.

File type.

Choice of the file type for data recording purposes:

- Cyclical: Cyclical/rotary memory (FIFO). When this file type is selected,

only one file can be simultaneously used.

- Linear: Linear memory. Once the memory is full, no more new data is

recorded by the analyzer.

Linear and cyclical files are not compatible between them.

The memory cannot simultaneously contain files of both types.

In case of a cyclical file, all the memory will be used by this file. No

memory can be allocated to another file.

If the type of file is changed, the memory will have to be formatted when

exiting setup.