-7-

•Connect the black or brown wire to the Si5580 “L” terminal of the AC power connector. That is the

line, or “hot” connection.

•Connect the white or blue wire to neutral. That’s the “N” terminal.

•Finally, and most importantly, connect the green wire to the GND terminal. That connects the

Si5580 metal enclosure and DC power supply ground to earth ground.

Always unplug the line cord from the wall before attaching it

to the Si5580

k

c

al

b

et

i

h

w

n

e

e

r

g

To Earth Ground

To Neutral

To Line (Hot)

To Earth Ground
To Neutral
To Line (Hot)

green

black or brown

white or blue

"Old Style"

AC Power Plug

"New Style"

AC Power Plug

Installing an AC Line Cord

Remove about 5 mm (3/16 inches) of insulation from each of the three wires of your line cord. (That’s

right, three wires. For safety, always use a three wire power cord on anything with a metal case.)

Depending on where you got your power cord, it may have black, white and green wires or brown/

blue/green.

The AC power plug that was shipped with your Si5580 might be one of two types. The “old style” is

shown in the diagram below, on the left. The “new style”, shown on the right, comes with an insulat-

ing rubber boot.

Make sure you follow the proper sketch for your connector style.