beautypg.com

Wiring inputs, Si5580, 24 vdc power supply – Applied Motion Si5580 User Manual

Page 13

background image

-13-

Wiring Inputs

The Si5580 input circuits can be used with

sourcing or sinking signals, 5 to 24 volts. This

allows connection to TTL circuits, PLCs, relays

and mechanical switches. Because the input

circuits are isolated, they require a source of

power. If you are connecting to a TTL circuit

or to a PLC, you should be able to get power

from the PLC or TTL power supply. If you are

using relays or mechanical switches, you will

need a 5-24 power supply. This also applies if

you are connecting the Si5580 inputs to another

Si product from Applied Motion, like the Si-1

and Si-100 indexers, or the Si3540 and 7080i

indexer-drives.

Connecting an Input to a Switch or Relay

Use normally open momentary switch to trigger Si5580 using Wait Input instruction.

Use single throw switch for parameter selection using If Input instruction.

Use normally open momentary switch for jogging.

2200

2200

2200

2200

2200

2200

inside Si5580

COM
COM

IN1

IN2

IN3

IN4

JOG CW

JOG CCW

Si5580

switch or relay

(closed=logic low)

IN

COM

5-24

VDC

Power

Supply

-

+

Note: If current is flowing into or out of an Si5580 input, the logic state of that input is low. If no

current is flowing, or the input is not connected, the logic state is high.

The diagrams on the following pages show how to connect Si5580 inputs to various devices.

The maximum voltage that can be applied to an input terminal is 24 volts

DC. Never apply AC voltage to an input terminal. Maximum current is 20

mA per input.