51
© 2 0 0 6 D i r e c t e d E l e c t r o n i c s
IIggn
niittiioon
n C
Coon
nttrroolllleed
d D
Doooorr L
Loocckkss O
On
n//O
Offff ((R
RE
ED
D)) - When on, the
doors will lock three seconds after the ignition is turned on and
unlock when the ignition is turned off.
Uncut – ignition controlled door locks on
Cut – ignition controlled door locks off
D
Diieesseell M
Mood
dee ((B
BL
LU
UE
E)) - Cut this loop if you have a diesel vehicle.
When cut the remote start will start the engine about 30 seconds
after pressing the
button once.
Uncut – Gas Mode
Cut – Diesel Mode
F
FA
AD
D//R
RA
AP
P C
Caan
ncceellllaattiioon
n ((G
GR
RE
EE
EN
N//B
BL
LA
AC
CK
K)) - This loop controls
when the Green/Black (H1/7) wire outputs a negative pulse either
before or after the remote start is active. Uncut the H1/7 wire will
pulse negative prior to remote start, this is normally used as a
Factory Alarm Disarm (FAD) output. When this loop is cut, the
Green/Black (H1/7) wire outputs a negative pulse after the remote
start shuts down, this is normally used to disable vehicles with
Retained Accessory Power (RAP) (e.g. the radio stays powered
until the doors are opened). Call Directed Technical Support if
your vehicle has the RAP feature.
Uncut – FAD
Cut – RAP Cancellation
V
Voollttaaggee M
Mood
dee//T
Taacch
hoom
meetteerr M
Mood
dee - Default is voltage mode. The
control module will automatically look at the tachometer input
PROG
PROG
ARM
ARM
DISARM