Directed Electronics Ready Remote User Manual
Page 43
39
© 2 0 0 6 D i r e c t e d E l e c t r o n i c s
T
TW
WO
O--R
RE
ESSIISST
TO
OR
R T
TY
YP
PE
E:: If two resistors are used in the factory
door lock switch/key cylinder, the door lock switch/key cylinder
will read resistance to ground in both directions.
D
DE
ET
TE
ER
RM
MIIN
NIIN
NG
G T
TH
HE
E P
PR
RO
OP
PE
ER
R R
RE
ESSIISST
TO
OR
R V
VA
AL
LU
UE
ESS:: To
determine the resistor values, the door lock switch/key cylinder
must be isolated from the factory door lock system. For testing, use
a calibrated digital multimeter that is set to ohms.
1.
Cut the output wire from the door lock switch/key cylinder in half.
2.
Test with the meter from the switch side of the cut door lock
switch/key cylinder wire to a reliable ground source. Some good
ground references are the ground input source to the door lock
switch/key cylinder or the battery ground.
3.
Operate the door lock switch/key cylinder in both directions to
determine the resistor values. If the multimeter displays zero resis-
tance in one direction, no resistor is needed for that direction.
4.
Once the resistor value(s) is determined, refer to the wiring dia-
gram for proper wiring.
note: Please refer to the Door Locking Systems document
on w
ww
ww
w..d
deessiiggn
ntteecch
h--iin
nttll..ccoom
m (On-Line Tech Support,
Tech Tips) for complete resistor test procedure and addi-
tional information for multiplexed door locks.
note: To ensure an accurate resistance reading, do not
touch the resistor or leads during testing.