beautypg.com

Directed Electronics Ready Remote User Manual

Page 43

background image

39

© 2 0 0 6 D i r e c t e d E l e c t r o n i c s

T

TW

WO

O--R

RE

ESSIISST

TO

OR

R T

TY

YP

PE

E:: If two resistors are used in the factory

door lock switch/key cylinder, the door lock switch/key cylinder

will read resistance to ground in both directions.

D

DE

ET

TE

ER

RM

MIIN

NIIN

NG

G T

TH

HE

E P

PR

RO

OP

PE

ER

R R

RE

ESSIISST

TO

OR

R V

VA

AL

LU

UE

ESS:: To

determine the resistor values, the door lock switch/key cylinder

must be isolated from the factory door lock system. For testing, use

a calibrated digital multimeter that is set to ohms.

1.

Cut the output wire from the door lock switch/key cylinder in half.

2.

Test with the meter from the switch side of the cut door lock

switch/key cylinder wire to a reliable ground source. Some good

ground references are the ground input source to the door lock

switch/key cylinder or the battery ground.

3.

Operate the door lock switch/key cylinder in both directions to

determine the resistor values. If the multimeter displays zero resis-

tance in one direction, no resistor is needed for that direction.

4.

Once the resistor value(s) is determined, refer to the wiring dia-

gram for proper wiring.

note: Please refer to the Door Locking Systems document
on w

ww

ww

w..d

deessiiggn

ntteecch

h--iin

nttll..ccoom

m (On-Line Tech Support,

Tech Tips) for complete resistor test procedure and addi-
tional information for multiplexed door locks.

note: To ensure an accurate resistance reading, do not
touch the resistor or leads during testing.