Hold Error:
The protective circuit in the unit activates
when the temperature inside the
automatic disc changer exceeds 60°C
(140°F), stopping all operation.
➪ Cool down the unit by opening
the windows or turning on the air
conditioner. As the temperature falls
below 60°C (140°F), the disc will start
playing again.
No Name:
Attempted to display DNPS during the CD
play having no disc names preset.
Waiting:
Radio text data is being received.
Load:
Discs are being exchanged in the Disc
changer.
Reading:
The unit is reading the data on the disc.
IN (Blink):
The CD player section is not operating
properly.
➪ Reinsert the CD. If the CD cannot be
ejected or the display continues to flash
even when the CD has been properly
reinserted, please switch off the power
and consult your nearest service center.
Protect (Blink): The speaker wire has a short-circuit or
touches the chassis of the vehicle, and
then the protection function is activated.
➪ Wire or insulate the speaker cable
properly and press the reset button.
Unsupported File:
An Audio file is played with a format that
this unit can’t support.
➪ ----
Copy Protection:
A copy-protected file is played.
➪ ----
Can’t Download:
Download Error:
This unit does not work properly for some
reason.
➪ Press the reset button to download
it again. If this error is still displayed,
consult a local Kenwood dealer.
No Display File:
No file that can be downloaded is
contained in the CD-ROM.
➪ Make sure that a files created with
referring to
Do not delete the extension (.kbm)
created when the file was created.
Incorrect File:
The file selected to be downloaded has a
format that this unit cannot read.
➪ Recreate the file.
Writing Error:
Writing failed while the file was
downloaded.
➪ Try the downloading again.
DEMO MODE (Blink):
The Demonstration mode has been
selected.
➪ The
(page 46) is ON. Turn it OFF.