Altera USB-Blaster II User Manual
Page 8

1–4
Chapter 1: Setting Up the USB-Blaster II Download Cable
Installing the USB-Blaster II Driver on Windows XP Systems
USB-Blaster II Download Cable
October 2014
Altera Corporation
User Guide
To access the download cable, the Quartus II software uses the built-in Red Hat USB
drivers, the USB file system (usbfs). By default, root is the only user allowed to use
usbfs. You must have system administration (root) privileges to configure the
USB-Blaster II download cable drivers.
1. Create a file named /etc/udev/rules.d/51-usbblaster.rules and add the following
lines to it. (The .rules file may already exist if you have installed an earlier
USB-Blaster version.)
c
There should be only three lines in this file, one starting with a comment
and two starting with BUS. Do not add extra line breaks to the .rules file.
2. Complete your installation by setting up the programming hardware in the
Quartus II software. Go to the
“Setting Up the USB-Blaster II Hardware with the
section on the following page.
f
For more information about USB-Blaster II driver installation, refer to the
Cable and Adapter Drivers web page
Installing the USB-Blaster II Driver on Windows XP Systems
You must have system administration (administrator) privileges to install the
USB-Blaster II download cable driver.
The download cable drivers are included in the Quartus II software installation.
Before you begin the installation, verify that the USB-Blaster II driver is located in
your directory: \
f
Follow the installation procedure found at this web page:
xp.html#note
.
Setting Up the USB-Blaster II Hardware with the Quartus II Software
1. Start the Quartus II software.
2. From the Tools menu, click Programmer.
3. Click Hardware Setup.
4. Click the Hardware Settings tab.
5. From the Currently selected hardware list, select USB-Blaster II.
6. Click Close.
7. In the Mode list, choose an appropriate programming mode.
Table 1–1 on
page 1–5
describes each mode.
# USB-Blaster II
BUS=="usb", SYSFS{idVendor}=="09fb", SYSFS{idProduct}=="6010", MODE="0666"