Cartridges & CEW Operation
The Smart cartridges can be reloaded independently. That is, if one of the two cartridges has been expended,
you can replace the expended cartridge with a new one. You do not have to wait until both cartridges have
been expended before reloading.
To replace the expended cartridge:
1
Point the CEW in a safe direction.
2
Ensure the safety switch is in the down (SAFE) position.
3
Press the cartridge release button.
4
Firmly pull the cartridge out of the bay by pulling on the upper tab and lower tab of the cartridge.
5
Keeping your hand away from the blast doors, gently push a new Smart cartridge into the cartridge bay
until an audible click is heard.
6
Verify that the cartridge is secure by pulling on the tabs on the lower and upper part of the cartridge.
7
Verify that the remaining Smart cartridge is secure by pulling on the tabs on the lower and upper parts of
the cartridge.