Unloading – Taser X2 User Manual
Page 37

37
Chapter 4
Cartridges & CEW Operation
Cartridge Release Button
Unloading
1
Point the CEW in a safe direction.
2
Ensure the safety switch is in the down (SAFE) position.
3
Keep your hands away from the front of the cartridges.
4
Press the cartridge release button with the index finger of your supporting hand.
5
Firmly pull the cartridge out of the bay by pulling on the upper tab and lower tab of the cartridge. If the
expended cartridge feels as if it is stuck in the cartridge bay and will not easily dislodge, try firmly pressing
on the cartridge release button directly below the individual cartridge that is difficult to remove.
NOTE: Use the left hand to unload cartridges beginning with the leftmost cartridge bay. By unloading from left
to right (or right to left if the right hand is used), it is less likely you will place fingers in front of the blast doors
of loaded cartridges.