REVERSE POLARITY

WARNING AND ERROR MESSAGE

WARNING AND ERROR MESSAGE

e6650 incorporates a variety of functions for the systems to verify

processes and the state of the electronics. In case of an error the

screen will display the cause of error and emit an audible sound.

Incorrect polarity connected.

Battery connection is interrupted.

Short-circuit of the output termination.

Input voltage incorrect.

The voltage of the battery pack has been

selected incorrectly!
The charger has malfunctioned for some

reason. Seek professional advice.
The voltage is lower than which is set.

Please check the number of cells in the

battery pack.

BATTERY CHECK
LOW VOLTAGE

BREAK DOWN

VOL SELECT ERR

INPUT VOL ERR

SHORT ERR

CONNECTION BREAK

The voltage is higher than which is set.

Please check the number of cells in the

battery pack.
Voltage of one cell in the battery pack is too

low, please check the voltage of each cell.
Voltage of one cell in the battery pack is too

high; please check the voltage of each cell.
Wrong connection of the connector detected;

please check the connector and cable.
The internal temperature is too high, please

cool down.
The processor cannot control the feeding

current, please repair it.

BATTERY CHECK
HIGH VOLTAGE

BATTERY VOLTAGE
CELL LOW VOL

BATTERY VOLTAGE
CELL HIGH VOL

BATTERY VOL ERR
CELL CONNECT

TEMP OVER ERR

CONTROL FAILURE