DISCHARGING OF LITHIUM BATTERY

DISCHARGING OF LITHIUM BATTERY

The value of discharge current on the left

can not exceed 1C, and the value on the

right can not be under the voltage

recommended by the manufacturer to avoid

deep discharging. Press START/ENTER for

more than 3 seconds to start discharging.

LiPo DISCHARGE
1.0A 11.1V(3S)

INC

INC

DEC

- +

INC

DEC

- +

Batt type

Stop

Start

Enter ‘>3 seconds’

This shows the real-time status of

discharging, you can press BATT

TYPE/STOP key to stop discharging.

Li3s 0.4A 12.59V
DSC 022:43 00682

BATTERY VOL ERR
CELL LOW VOL

4.14 4.16 4.09
2.18 0.00 0.00

Number

of cells

Elapsed

time

Discharge

current

Battery

voltage

Discharged

capacity

The processor monitors voltage of each cell when the battery packs

are during its “storage” and “discharging” process. If voltage of any

cell is abnormal, e6650 will show error message and terminate the

program forcibly. So if there is battery damage or disconnection, you

can see the error message and press INC to know which cell is

damaged.

VOLTAGE BALANCING AND MONITORING IN THE

DISCHARGE PROCESS

The processor detects voltage of one cell is

too low.

The 4th cell was damaged. The value of

voltage may be zero if disconnection occurs.