10 product overview – Lab.gruppen LM 44 User Manual
Page 16

10
Product Overview
Lake LM Series Operation Manual Rev 1.2.8
GPIO Connector
A 9-pin GPIO (General Purpose Input Output) connection is provided to enable integration with external
systems such as alarm/fire systems, providing basic control of power state, mute along with fault notifica-
tion to an external monitoring system. Please refer to sections 6.10.4.4 and 7.4 for further details.
Mains Power Connector
A universal power supply capable of accepting 70-265 V ~ 50-60 Hz : 25 W is built into LM Series devices.
The IEC power cable provided includes a locking feature via a pin on the bottom of the connector; the
connector can accept standard or locking IEC power cables.
The power supply must be connected to AC mains using a power cable with a correctly wired plug for the
country of operation.