Typical wiring diagrams, Page 4 – IOTA ICE-420-EM-B User Manual
Page 4
![background image](/manuals/738110/4/background.png)
Page 4
TYPICAL WIRING DIAGRAMS
Use in conjunction with Rapid Start ballasts and 4 pin lamps only
Rev. 071513
68142-011
1. ONE LAMP RAPID START BALLAST
2. TWO LAMP RAPID START BALLAST WITH ONE LAMP EMERGENCY OPERATION
3. TWO LAMP RAPID START BALLAST WITH TWO LAMP EMERGENCY OPERATION
BLUE
BLUE
RED
RED
BLK (120V)
ORG (277V)
WHITE
WHT/BLK
BLUE
BLU/WHT
YELLOW
RED/WHT
RED
*A.C./EMERGENCY LAMP
ONE LAMP
A.C.
BALLAST
➀
➀
➁
➁
➂
➂
VIOLET
VIOLET
RED OR RED/BLK (+)
WHT/RED
WHT/BLK
WHT/BLK
CHARGE
INDICATOR
UNIT CONNECTOR
SELECT PROPER VOLTAGE LEAD, CAP UNUSED LEAD
LAMP SELECTOR LEADS. REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER APPLICATION.
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.
FOR 277V INSTALLATION, CAP BLK/ORG AND BLK SEPARATELY.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
UNSWITCHED
LINE
COMMON
SWITCHED OR
UNSWITCHED
LINE
WHITE
BLACK
*LAMP
EMERGENCY
BALLAST
1LRSB_ICE420B
ONE LAMP RAPID START BALLAST
➃
FIXTURE
GROUND
BLK/ORG
TEST
SWITCH
➃
➄
➄
BLUE
BLUE
RED
RED
BLK (120V)
ORG (277V)
WHITE
WHT/BLK
BLUE
BLU/WHT
YELLOW
RED/WHT
RED
*A.C./EMERGENCY LAMP
TWO LAMP
A.C.
BALLAST
➀
➀
➁
➁
➂
➂
VIOLET
VIOLET
RED OR RED/BLK (+)
WHT/RED
WHT/BLK
WHT/BLK
CHARGE
INDICATOR
UNIT CONNECTOR
SELECT PROPER VOLTAGE LEAD, CAP UNUSED LEAD
LAMP SELECTOR LEADS. REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER APPLICATION.
DO NOT MATE CONNECTORY UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.
FOR 277V INSTALLATION, CAP BLK/ORG AND BLK SEPARATELY.
TEST ACCESSORY LEADS-REFER TO ISNTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
UNSWITCHED
LINE
COMMON
SWITCHED OR
UNSWITCHED
LINE
WHITE
BLACK
YEL
YEL
LAMP
*LAMP
TWO LAMP RAPID START BALLAST WITH ONE LAMP EMERGENCY OPERATION
2LRSB_1LEO_ICE420B
EMERGENCY
BALLAST
➃
➃
FIXTURE
GROUND
BLK/ORG
TEST
SWITCH
➄
➄
BLUE
BLUE
RED
RED
BLK (120V)
ORG (277V)
WHITE
WHT/BLK
BLUE
BLU/WHT
YELLOW
RED/WHT
RED
*A.C./EMERGENCY LAMP
TWO LAMP
A.C.
BALLAST
➀
➀
➁
➁
➂
➂
VIOLET
VIOLET
RED OR RED/BLK (+)
WHT/RED
WHT/BLK
WHT/BLK
CHARGE
INDICATOR
UNIT CONNECTOR
SELECT PROPER VOLTAGE LEAD, CAP UNUSED LEAD
LAMP SELECTOR LEADS. REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER APPLICATION.
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.
FOR 277V INSTALLATION, CAP BLK/ORG AND BLK SEPARATELY.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
UNSWITCHED
LINE
COMMON
SWITCHED OR
UNSWITCHED
LINE
WHITE
BLACK
YEL
YEL
*LAMP
*LAMP
EMERGENCY
BALLAST
2LRSB_2LEO_ICE420B
TWO LAMP RAPID START BALLAST WITH TWO LAMP EMERGENCY OPERATION
➃
➃
FIXTURE
GROUND
BLK/ORG
TEST
SWITCH
➄
➄
ICE-420-
EM-B
ICE-420-
EM-B
ICE-420-
EM-B