IOTA I-420-EM-B User Manual
I-420-em-b, Instruction manual, Important safeguards
I-420-EM-B
INSTRUCTION MANUAL
TBTS SERIES AC
10W–57W RAPID START
4 PIN COMPACT LAMP
EMERgENCy LIghTINg EquIPMENT
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1.
CAUTION – To prevent electrical shock, do not mate unit connector until installation is complete and A.C.
power is supplied to the unit.
2.
CAUTION – This fixture provides more than one power supply output source. To reduce the risk of electrical
shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by discon-
necting the unit connector.
3.
CAUTION – This is a sealed unit. The integral, high temperature Ni-Cad battery is not replaceable. Replace
the entire unit when necessary and recycle or dispose of the nickel-cadmium battery properly.
4.
DO NOT USE OUTDOORS. The I-420-EM-B is for use with grounded, uL Listed, damp location rated, indoor
fixtures. Not for use in heated air outlets or hazardous locations.
5. The
I-420-EM-B requires an unswitched A.C. power source of either 120 or 277 volts. Properly cap the
unused A.C. lead.
6. When the
I-420-EM-B is installed on the same branch circuit, refer to Illustration 3, Figures A and B for input
wiring. When installed on separate branch circuits, refer to Illustration 3, Figures C and D for input wiring. Per
NEC, the
I-420-EM-B and A.C. ballast must be on the same panel board.
7. Do not mount near gas or electric heaters.
8. The
I-420-EM-B should be mounted in locations and at heights where it will not readily be subjected to tam-
pering by unauthorized personnel.
9. The
I-420-EM-B will cold strike and operate one 10W through 57W, or two 10W through 26W, 4-pin Rapid
Start compact fluorescent lamps. Contact customer service for additional lamp usage.
10. The
I-420-EM-B is compatible with most electronic A.C. ballasts (including multiple lamps) as follows:
Electronic ballasts – one or two lamp emergency operation.
11. Suitable for use in damp locations and enclosed and gasketed fixtures.
12. When used in conjunction with enclosed and gasketed fixtures, the
I-420-EM-B is suitable for mounting in the
ballast compartment only.
13. For use in 0° C minumum, 50° C maximum ambient temperatures.
14. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition, void
warranty, and result in non-compliance with uL specifications.
15. Do not use this equipment for other than intended use.
16. Install in accordance with the National Electrical Code and local regulations.
17. Installation and servicing should be performed by qualified personnel.
18. Lighting fixture manufacturers, electricians, and end-users need to ensure product system compatibility before
final installation.
SAVE THESE INSTRUCTIONS