Troubleshooting, Programmable serial controller 19 – Hall Research HR-4P User Manual

Page 21

background image


Programmable Serial Controller

19

5. Troubleshooting

There are no field serviceable parts or circuits inside the device. If you
think that the device is malfunctioning (or you have no picture output),
please confirm that the unit contains the proper user programmed
information and that the switch is in the RUN position.

If you are having trouble configuring or communicating with the HR-4P unit, check:

UNIT SEEMS DEAD

Check that the unit is powered with the supplied
power supply and operating normally.

With SWITCH in RUN Position the LED
should be on SOLID
With SWITCH in PRG Position the LED
should be BLINKING

GUI WONT RUN

Verify that program installs without errors and the OS
is fully patched and up to date

Verify that the .NET Framework 2.0 minimum has
been installed

COMMUNICATIONS PROBLEMS WITH GUI

Set switch to PRG position when using the GUI

The LED should be BLINKING

Ensure RS232 cable used is compatible with the PC
being used

This is normally a NULL-MODEM cable with
pins 2 & 3 crossed.
Only Pins 2, 3 and 5 are used for serial
communication

Ensure PC COM port is set correctly on the
COMMUNICATIONS TAB

Ensure that the GUI Command Format matches the
actual units setting

Check GUI Setting on TOOLS Menu.
Factory Default is LONG COMMAND
FORMAT

UNIT DOESN’T CONTROL SERIAL DEVICE

Verify unit and Serial Device have proper serial
interconnect cabling

Straight Cable or Null-Modem

Verify via PC and HyperTerminal that unit outputs
proper characters at proper baud rate when the
appropriate event occurs.

Verify serial device can be controlled via
HyperTerminal or similar program

Set switch to RUN position when unit is put into service

The LED should be on solid