Introduction – Glow-worm Clearly Hybrid - Compact System User Manual
Page 7
0020096883_01 - 06/10 - Glow-worm
- 5 -
INTRODUCTION
2.3
Example of Installation – Diagram 9 (9.2) : HYBRID COMPACT with 2 low heating temperature
zones (30-40°C) or 2 high heating temperature zones (< 80°C)
14 2 port valve "heating zone 1"
15 Overheating safety (if underfl oor heating)
16 Glycol PRV discharge
17 Heat pump circuit fi lter (not supplied)
A
Heat pump circuit return
B
Heat pump circuit fl ow
C
Cold water supply
D
Domestic hot water fl ow
E Boiler
circuit
fl ow
F
Boiler circuit return
G Heating
circuit
fl ow
H
Heating circuit return
I
Heat pump circuit safety valve discharge
Key
1 Heat
pump
2
Systempro control unit
3
"Compact" hydraulic module
4
Heat pump electrical supply + protection (This must have it's
own single isolation)
5
Wireless outdoor sensor
6
Domestic hot water cylinder
7 EBUS
boiler
8
Climapro2 RF programmable wireless room thermostat "zone 2"
9
Heating circuit "zone 2" (UFH shown, but can be underfl oor or
radiators)
10 2 port valve "heating zone 2"
11 Domestic hot water cylinder 2 port valve
12 Climapro2 RF programmable wireless room thermostat "zone 1"
13 Heating circuit "zone 1" (UFH shown, but can be underfl oor or
radiators)
i
Refer to the chapters “Hydraulic connection” and
“Electrical Connection” to connect the system.
i
DHW components only necessary with sealed
system or open vented installations. Hot water
production can be via a combi boiler instead.
b
This diagram shows the case of an installation with a
dual zone low temperature heating fl oor
(= outlet temperature < 40°C).
Zones must be same temperatures.
EBUS
G
H
B
A
E
F
I
230V
D
C
2
1
3
4
11
5
7
6
8
9
10
14
15
12
13
17
16