Installation – Glow-worm Clearly Hybrid - Compact System User Manual
Page 25
0020096883_01 - 06/10 - Glow-worm
- 23 -
INSTALLATION
12.7.5 Resetting
parameters
This feature allows you to reset the parameters of the control
unit (factory setting).
b
The resetting of factory settings is irreversible.
Any customised confi guration of the control unit
will be lost.
• Using the buttons
,
select Settings reset on the screen.
• Press the button
to confi rm.
• Increase or decrease with the
buttons
to display the
desired value.
• Press the button
to confi rm.
• Press the button
.
12.8 Commissioning
This menu allows you to carry out the necessary operations on
the appliances following installation.
• Using the buttons
, select
Commissioning
on the screen.
• Press the button
to confi rm.
12.8.1
Filling the heating circuit
i
The Systempro control unit is used to open the
valves of each zone during fi lling, if more than one
heating zone is installed.
• Select
Fill htg circuit
on the screen
using the buttons
.
• Press the button
to confi rm.
The screen shows the pressure
measured in the system.
• Activate
fi lling mode by pressing the
button
.
• Refer to the boiler instructions for
fi lling the boiler.
The screen displays the pressure
measured in the system and that
installation fi lling is in progress.
• To
stop
fi lling press the button
.
• Close
the
fi lling loop.
• Press the button
to confi rm.
12.8.2
Venting the heating circuit
Venting of the heating circuit enables the purging of any air in
the heating circuit.
• Using the buttons
,
select Air venting on the screen.
• Press the button
to confi rm.
• Open the different heating circuit air vent.
• Using the buttons
,
select Vent heating circuit on the
screen.
• Press the button
to confi rm.
• Confi rm with the button
in
order to begin the venting process.
The venting process is carried out for
15 minutes. You can simultaneously run
the venting of the HP circuit.
• Press the button
.
b
When venting is complete, close the different
heating circuit air vent.