0020096883_01 - 06/10 - Glow-worm

- 23 -

INSTALLATION

12.7.5 Resetting

parameters

This feature allows you to reset the parameters of the control
unit (factory setting).

b

The resetting of factory settings is irreversible.
Any customised confi guration of the control unit
will be lost.

• Using the buttons

,

select Settings reset on the screen.

• Press the button

to confi rm.

• Increase or decrease with the

buttons

to display the

desired value.

• Press the button

to confi rm.

• Press the button

.

12.8 Commissioning

This menu allows you to carry out the necessary operations on
the appliances following installation.

• Using the buttons

, select

Commissioning

on the screen.

• Press the button

to confi rm.

12.8.1

Filling the heating circuit

i

The Systempro control unit is used to open the
valves of each zone during fi lling, if more than one
heating zone is installed.

• Select

Fill htg circuit

on the screen

using the buttons

.

• Press the button

to confi rm.

The screen shows the pressure
measured in the system.

• Activate

fi lling mode by pressing the

button

.

• Refer to the boiler instructions for

fi lling the boiler.

The screen displays the pressure
measured in the system and that
installation fi lling is in progress.

• To

stop

fi lling press the button

.

• Close

the

fi lling loop.

• Press the button

to confi rm.

12.8.2

Venting the heating circuit

Venting of the heating circuit enables the purging of any air in
the heating circuit.

• Using the buttons

,

select Air venting on the screen.

• Press the button

to confi rm.

• Open the different heating circuit air vent.

• Using the buttons

,

select Vent heating circuit on the
screen.

• Press the button

to confi rm.

• Confi rm with the button

in

order to begin the venting process.

The venting process is carried out for
15 minutes. You can simultaneously run
the venting of the HP circuit.

• Press the button

.

b

When venting is complete, close the different
heating circuit air vent.