INSTALLATION

8

Filling the heating circuit

i

In the case of a multi-zone installation, fi ll the
heating circuit using the “Filling” mode when
commissioning the control box. “Filling” mode
ensures fi lling by automatically opening all of the
circuit. Refer to the chapter “Commissioning the
Systempro

control unit ► Commissioning ► Filling

the heating circuit".

• For single zone installations (diagram 9.1), please refer to

your boiler installation manual for fi lling of the heating circuit.

• For mutiple zone installations (diagram 9.2, 9.3) please refer

to chapter "Commissioning ► Filling the heating circuit" for
instructions on confi guring the systempro control box for
fi lling multiple zones.

9

Activating the heat pump

1

Key
1 ON/OFF

button

• Switch ON the circuit breaker which is located on the

electrical panel and connected to the heat pump.

• Switch ON the heat pump button (1). Check that the green

LED located on the heat pump’s motherboard is on.

i

To locate the LEDs on the PCB, see the "Wiring
diagram" chapter in the heat pump instructions.

10 Activating the boiler

• Refer to the boiler instructions in order to adjust the boiler.

b

Ensure that the maximum heating temperature is
compatible with the installation.

b

Make sure the boiler pump is not in permanent
mode.

11 Activating the room thermostat

1

2

3

Key
1 Battery

cover

2 Protective

cover

3 Room

thermostat

• Remove the protective cover (2) located in the battery

compartment following the order (A) to (C).

• The main screen of the room thermostat is displayed.

12 Activating the control unit

a

Ensure that the heat pump and heating circuits
have been fi lled.

e

Ensure that all the electrical connections have
been made.

• Switch ON the circuit breaker which is located on the

electrical panel and connected to the control unit.

1

Key
1

Switch On (I) / Off (O)

• Turn on the control unit (1) with the switch (2) in position (I).