Maintenance, 16 servicing – Glow-worm Clearly Hybrid - Compact System User Manual
Page 33
0020096883_01 - 06/10 - Glow-worm
- 31 -
MAINTENANCE
16 Servicing
16.1 Annual
Maintenance
• Consult each of the system component’s instructions for
more information about the corresponding maintenance
operations.
16.2 Control unit maintenance menu
The maintenance menu includes the installation menu function,
plus 2 additional functions.
• Press the button
for 7
seconds.
• Enter the installer maintenance
access code (35).
• Press the button
to confi rm.
16.2.1 Test
menu
This menu allows you to test the operation of all appliances and
the system (boiler, HP, zone valves,) present in the installation.
• Using the buttons
,
select System tests on the screen.
• Press the button
to confi rm.
Boiler test
• Using the buttons
,
select Boiler on the screen.
• Press the button
to confi rm.
This menu allows you to issue a heating
demand to the boiler.
• Press the button
to activate
the heating demand.
• Press the button
to disable the
heating demand.
• Press the button
.
Heat pump test
• Using the buttons
,
select Heat pump on the screen.
• Press the button
to confi rm.
This menu allows you to:
- issue a heating demand to the heat
pump,
- activate the pump
- activate the fan
- activate the 4-way valve
- activate the crankcase heater
- activate the electrical resistance
heater
- activate the heat exchanger’s
resistance heater
- activate the defrosting
• Using the buttons
, make
your selection on the screen.
• Confi rm with the button
to start
the test.
• To stop the test, press the button
.
• Press the button
.
System test
• Using the buttons
,
select System on the screen.
• Press the button
to confi rm.
This menu allows to activate the
hydraulic module pump.
• Press the button
to activate
the test.
• To disable the test, press the button
.
• Press the button
.