0020096883_01 - 06/10 - Glow-worm

- 31 -

MAINTENANCE

16 Servicing

16.1 Annual

Maintenance

• Consult each of the system component’s instructions for

more information about the corresponding maintenance
operations.

16.2 Control unit maintenance menu

The maintenance menu includes the installation menu function,
plus 2 additional functions.

• Press the button

for 7

seconds.

• Enter the installer maintenance

access code (35).

• Press the button

to confi rm.

16.2.1 Test

menu

This menu allows you to test the operation of all appliances and
the system (boiler, HP, zone valves,) present in the installation.

• Using the buttons

,

select System tests on the screen.

• Press the button

to confi rm.

Boiler test

• Using the buttons

,

select Boiler on the screen.

• Press the button

to confi rm.

This menu allows you to issue a heating
demand to the boiler.

• Press the button

to activate

the heating demand.

• Press the button

to disable the

heating demand.

• Press the button

.

Heat pump test

• Using the buttons

,

select Heat pump on the screen.

• Press the button

to confi rm.

This menu allows you to:
- issue a heating demand to the heat
pump,
- activate the pump
- activate the fan
- activate the 4-way valve
- activate the crankcase heater
- activate the electrical resistance
heater
- activate the heat exchanger’s
resistance heater
- activate the defrosting

• Using the buttons

, make

your selection on the screen.

• Confi rm with the button

to start

the test.

• To stop the test, press the button

.

• Press the button

.

System test

• Using the buttons

,

select System on the screen.

• Press the button

to confi rm.

This menu allows to activate the
hydraulic module pump.

• Press the button

to activate

the test.

• To disable the test, press the button

.

• Press the button

.