INSTALLATION

• Using the buttons

,

select Connection on the screen.

• Press the button

to confi rm.

• Press the button on the outdoor

sensor to connect.

ON

1

Key
1

Outdoor sensor button

i

Once the sensor is detected, the message
«Connection completed» is displayed.
If unsuccessful, the message "Connection failure" is
displayed.
Press the button

and repeat the operation.

• Press the button

.

i

The External T°C Correction allows you to correct
the temperature measured by the outdoor sensor
(+/- 5 ° C, at intervals of 1 ° C - factory setting: 0).

• Using the buttons

,

select External T ºC correction on
the screen.

• Press the button

to confi rm.

This setting is automatically modifi ed in
the installer room thermostat menu.

• Increase or decrease with the

buttons

to display the

desired correction.

• Press the button

to confi rm.

• Press the button

twice.

12.6 Self

check

e

Do not modify the cables when connected to the
mains.

The automatic test allows you to check:

- EBUS inputs,

- NTC inputs,

- the RF connection with the room thermostat,

- the outdoor sensor radio connection.

The other connections are not tested and should be
visually inspected during installation or confi guration
modifi cations.

• Using the buttons

,

select Self check on the screen.

• Press the button

to confi rm.

• Check that all installation’s

components are switched on.

• Confi rm the start of the test with the

button

.