Installation – Glow-worm Clearly Hybrid - Compact System User Manual
Page 20
0020096883_01 - 06/10 - Glow-worm
- 18 -
INSTALLATION
12.2 Wiring
summary
e
To check or modify a connection:
• Set the control box switch to the Off (O)
position.
• Set the circuit breaker located on the
electrical panel and connected to the control
box to the Off position.
• Press the button
.
Via the screen, you will be asked to
verify, step by step, the connections you
made to the control unit.
• If the connections are correct,
confi rm with the button
.
• If they are not correct, disconnect
the control unit’s power supply and
complete the necessary wiring as
indicated.
• Once completed, connect on the
control unit’s power supply and
confi rm with the button
.
Once the control unit has been
reconnected, it returns to the current
control function.
• Press the button
.
12.3 "Thermostat / sensor" menu
• Using the buttons
,
select Rmstat/sensor on the screen.
• Press the button
to confi rm.
12.4 Thermostat(s)
• Using the buttons
,
select Roomstat(s) on the screen.
• Press the button
to confi rm.
• Using the buttons
,
select the area controlled by the
room thermostat.
• Press the button
to confi rm.
On the room thermostat:
• Press the button
for 7
seconds.
• Enter the professional access code
(96).
• Via the installer menu > select > RF
> pairing.
• Press the room thermostat button
.
The control unit and the room
thermostat display “Connection fi nished
" on the respective screen.
If the message "Connection failed" is
displayed, press the button
and
repeat the operation.
• Repeat these operations for each
room thermostat (the zone number
is displayed on the thermostat at the
end of pairing).
• Press the button
twice.
12.5 Outdoor
sensor
• Using the buttons
, select
Outdoor sensor
on the screen.
• Press the button
to confi rm.