Other functions and settings, Switch ( sw2 ) function setting, Rc max distance setting – FeiYu Tech FY-41AP Lite User Manual
Page 32: 1 switch ( sw2 ) function setting, 2 rc max distance setting

Guilin Feiyu Electronic Technology Co., Ltd.
Guilin Feiyu Electronic Technology Co., Ltd http://www.feiyu-tech.com [email protected]
Page 30
10. Other Functions And Settings
10.1 Switch ( SW2 ) Function Setting
You can select the Auto Circling Mode which control by SW2.The navigation models
of FY-41AP Lite show in the table, we can just select two modes for SW2 at the same
time.
SW2 Mode
Function
Remark
Null
SW-2 Deactivated
SW-2 set to NULL, Flying mode is controlled by
SW-1.
Go Home
Auto Return To Launch
On activation, plane will automatically return to
launch (RTL) point.
Line
Fixed altitude & Heading lock
flight Mode
With no controlling input from the pilot, the
plane will automatically lock current heading &
maintain altitude.
Circle
Auto Circling Mode (ACM)
Automatically fly, circling a fixed point. Centre is
at point of ACM activation.
You can set the SW2 functions by using
―FYGCS 5.11 for 41&DOS‖ software. After
FY-41AP Lite connect to the GCS software successfully, you can select
―Menu->Autopilot Setting->RC Setting‖ to finish the switch mode setting.
10.2 RC Max Distance Setting
The RC Max Distance Setting will not allow the plane to fly beyond the distance you
have set. Upon reaching this distance, the FY-41AP Lite will automatically engage RTL
and fly back to you.