Band information – EXFO MaxTester MAX-630 User Manual
Page 94
Running DSL/IP Tests and Viewing Results
88
MAX-630
Band Information
Band Information
The Band Information tab allows you to view a list of individual upstream
or downstream band parameter details.
When the Test Interface for Auto or Manual Test is set to ADSL2+ or
VDSL2 bonding mode, there will be 2 pages of results, one for each DSL
line-pair.
To access the second-pair results, press the Pair 1/2 function key at the
bottom-right of the screen.
The page contains Upstream and Downstream
parameters. Press
to toggle between bands.
ADSL lists only 1 of each.
VDSL lists US0 to 3 and DS1 to 3 possible
bands, depending on the band plan.
Parameter - Downstream/Upstream
SNR Margin is the measured current
signal-to-noise ratio margin across all active
sub-carriers, as an amount of increased noise
relative to the measured noise power that the
system would be able to tolerate. Only a value
of 6 or above is able to support a bit error rate of 10
-7
.
Loop Attenuation is the current quality of the line and is measured
only once during testing.
Signal Attenuation is the current reduction of signal strength and
is measured periodically when the line is connected.
Tx Power is the upstream/downstream transmitting power for the
selected band.