9 certification, Ir accessories and calibration gas, Eries – ENMET EX-6165 User Manual
Page 17
EX-6120, 6165 SERIES IR
ENMET Corporation
14
9 Certification
The
EX-6120,
6165
S
ERIES
IR
(FGD10 Series) of Gas Detectors are ATEX and IECEx certified for use in potentially
explosive atmospheres and is marked as follows:-
** Denotes additional characters that define the gas detector configuration e.g. Enclosure type and sensor arrangement.
YYYY – Denotes year of manufacture.
Special Conditions of Safe Use
Only Loctite 243 or a compound of equal strength shall be reapplied to the threads of the sensor after replacing the
sensing element
Electrical data
Power supply - 8Vdc to 24Vdc, 5W
Relay contact rating – 300Vac, 3 Amps
Installation instructions
The cable entry devices and blanking elements of unused apertures shall be of a certified flameproof type, suitable for
the conditions of use and correctly installed.
With the use of conduit, a suitable certified sealing device such as a sealing fitting with compound shall be provided
immediately at the entrance to the flameproof enclosure.
10 EX-6120, 6165 S
ERIES
IR Accessories and Calibration Gas
EX-6120, 6165 S
ERIES
IR
partial list of typical accessories and calibration gas
ENMET
part number
Description of Accessory
Part Number
Sensor
Contact
ENMET Corp
Calibration Adaptor
(for sensors without weather guard)
03700-058
Regulator Assembly
02506-004
Calibration Gas, 50%LEL Methane
(for 0 – 100% LEL CH4)
03220-050
Calibration Gas, 2000ppm CO2
(for 0 – 500ppm CO2)
03220-2000
Weather Guard
04546-012
Maintenance Tool, Sensor
73413-210
WARNING – DO NOT OPEN WHEN AN EXPLOSIVE GAS
ATMOSPHERE IS PRESENT
GAS DETECTOR TYPE FGD10 **
STATUS SCIENTIFIC
IECEx SIR 08.0009X
CONTROLS LTD.
T4 (Ta -20
O
C to +60
O
C)
MANSFIELD
NG18 5ER.UK.
II 2 G Ex d IIC 1180
SIRA 08ATEX1031X
SERIAL No. XXXXXX
CIRCUIT RATING: 24VDC, 5W
YYYY
RELAY CONTACT RATING:
300VAC. 3A MAX.