beautypg.com

Ack nak timeout value – Datalogic Scanning QUICKSCAN QD2100 User Manual

Page 64

background image

RS-232/USB-Com Interfaces

56

QuickScan® QD2100

ACK NAK Timeout Value

This option specifies the amount of time the reader waits for an ACK character from the
host following label transmission. The selectable timeout range is 200 milliseconds to
15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout.

To set this value:

1. Determine the desired setting in milliseconds.

2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with

leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming

Mode.

4. Scan the barcode: SELECT ACK NAK TIMEOUT VALUE SETTING.

5. Scan the appropriate two digits from the keypad in

Appendix E, Keypad

, that represent

the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming

Mode.

This completes the procedure. See

Table 10

for some examples of how to set this feature.

Table 10. ACK NAK Timeout Value Setting Examples

NOTE

If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.

STEP

ACTION

EXAMPLES

1

Desired Setting

200ms

1,000ms (1 sec.) 5200ms (5.2 sec.)

15,000ms (1 sec.)

2

Divide by 200

01

05

26

75

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT ACK NAK TIMEOUT VALUE SETTING

5

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘1’

‘0’ and ‘5’

‘2’ and ‘6’

‘7’ and ‘5’

7

Scan ENTER/EXIT PROGRAMMING MODE