QuickScan® QD2100

LED and Beeper Indications

INDICATION

DESCRIPTION

LED

BEEPER

Power-up Beep

The imager is in the process of pow-
ering-up.

Imager beeps four times at highest
frequency and volume upon power-
up.

Good Read Beep

A label has been successfully
scanned by the imager.

LED behavior for this indica-
tion is configurable via the
feature “

Good Read: When to

Indicate

The imager will beep once at cur-
rent frequency, volume, mono/bi-
tonal setting and duration upon a
successful label scan.

ROM Failure

There is an error in the imager's
software/programming

Flashes

Imager sounds one error beep at
highest volume.

Limited Scanning
Label Read

Indicates that a host connection is
not established when the IBM or
USB interface is enabled.

N/A

Imager 'chirps' six times at the high-
est frequency and current volume.

Imager Active
Mode

The imager is active and ready to
scan.

The LED is lit steadily

a

a.

Except when in sleep mode or when a

Good Read LED Duration

other than 00 is selected

N/A

Imager
Disabled

The imager has been disabled by
the host.

The LED blinks continuously

N/A

Green Spot is on
continuously

While in Stand Mode or Trigger
Object Sense mode the green spot
shall be on while in stand watch
state.

N/A

N/A

Green Spot

a

flashes momen-
tarily

Upon successful read of a label, the
software shall turn the green spot on
for the time specified by the config-
ured value.

N/A

N/A

Programming Mode - The following indications ONLY occur when the imager is in Programming Mode.

Label Programming
Mode Entry

A valid programming label has been
scanned.

LED blinks continuously

Imager sounds four low frequency

beeps.

Label Programming
Mode Rejection of
Label

A label has been rejected.

N/A

Imager sounds three times at low-
est frequency & current volume.

Label Programming
Mode Acceptance
of Partial Label

In cases where multiple labels must
be scanned to program one feature,
this indication acknowledges each
portion as it is successfully
scanned.

N/A

Imager sounds one short beep at

highest frequency & current volume.

Label Programming
Mode Acceptance
of Programming

Configuration option(s) have been
successfully programmed via labels
and the imager has exited Program-
ming Mode.

N/A

Imager sounds one high frequency
beep and 4 low frequency beeps
followed by reset beeps.

Label Programming
Mode Cancel Item
Entry

Cancel label has been scanned.

N/A

Imager sounds two times at low fre-
quency and current volume.