beautypg.com

Code 39 — cont, Code 39 set length 2 – Datalogic Scanning QUICKSCAN QD2100 User Manual

Page 173

background image

Code 39

Product Reference Guide

165

Code 39 — cont.

Code 39 Set Length 2

This feature specifies one of the barcode lengths for

Code 39 Length Control

. Length 2

is the maximum label length if in

Variable Length

Mode, or the second fixed length if

in

Fixed Length

Mode. Length includes the barcode’s check, data, and full-ASCII shift

characters. The length does not include start/stop characters.

The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length
(only one fixed length).

Follow these instructions to set this feature:

1. Determine the desired character length (from 1 to 50 — or 0 to ignore this length). Pad

the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20,
etc.

2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming

Mode.

3. Scan the barcode: SELECT CODE 39 LENGTH 2 SETTING.

4. Scan the appropriate two digits from the keypad in

Appendix E, Keypad

, that represent

the length setting which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming

Mode.

This completes the procedure. See

Table 22

for some examples of how to set this feature.

Table 22. Code 39 Length 2 Setting Examples

NOTE

If you make a mistake, before the last character scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.

STEP

ACTION

EXAMPLES

1

Desired Setting

00 (Ignore This

Length)

07 Characters

15 Characters

50 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT CODE 39 LENGTH 2 SETTING

4

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘0’

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

5

Scan ENTER/EXIT PROGRAMMING MODE