Plow, Rt55 t4i operator’s manual – Ditch Witch RT55 User Manual
Page 141

Service - 140
RT55 T4i Operator’s Manual
500 Hour
Plow
Change Plow Vibrator Oil
Change plow vibrator oil every 500 hours. If normal ambient operating temperature exceeds 100°F (38°C),
change plow vibrator oil every 250 hours.
To change:
1.
Open fill (2) to vent vibrator.
2.
Drain oil at drain plug (1).
3.
Replace plug and move plow vibrator to horizontal position.
Fill with MPL at fill (2) until oil is halfway up sight glass (3). Capacity is 3.5 qt (3.3 L).
IMPORTANT: Do not drain oil from plow vibrator when hot. Let vibrator cool before removing drain plug.
See also other documents in the category Ditch Witch Special machinery:
- JT5 (161 pages)
- JT922 (159 pages)
- JT9 (165 pages)
- JT20 (195 pages)
- JT1220 (201 pages)
- JT2020 (203 pages)
- JT25 (203 pages)
- JT30 (245 pages)
- JT60 (218 pages)
- JT100 (243 pages)
- AT Air Hammer (11 pages)
- TK Series Manual (61 pages)
- 8500 (77 pages)
- MR90 (121 pages)
- FT5 (28 pages)
- FM5 (57 pages)
- FM13V (46 pages)
- FM25 (67 pages)
- P80 (71 pages)
- OnGrade (63 pages)
- FX20 (100 pages)
- FX25 (119 pages)
- FX30 (149 pages)
- FX50 (141 pages)
- FX60 (157 pages)
- MV800 (111 pages)
- RT Line (115 pages)
- RT30 (97 pages)
- RT45 (203 pages)
- RT100 (161 pages)
- RT115 (252 pages)
- RT120 (223 pages)
- Zahn (105 pages)
- RT80 (203 pages)
- RT115 Q (193 pages)
- RT120 Q (211 pages)
- 100SX (50 pages)
- 410SX (131 pages)
- SK350 (77 pages)
- SK750/SK755 (81 pages)
- SK850 (107 pages)
- SK850 Footings Machine (107 pages)
- 150RT (55 pages)
- 250RT (49 pages)