Check hydraulic fluid level, Check hydraulic fluid cooler – Ditch Witch RT Line User Manual
Page 81
Service - 80
RT12/RT16/RT20/RT24 Operator’s Manual
Each Use
CMW
Check Hydraulic Fluid Level
With digging boom fully raised, check hydraulic
fluid at sight glass (1) before each use. If low, add
SAE15W40 with PowerUp additive until fluid level
is at mid-level in sight glass. Clean dust from cap
(2) by blowing with low pressure air.
Add 16 oz (0.47 L) of Power Up oil additive or equivalent to 8 gal (30.28 L) of SAE15W40 for use as
hydraulic fluid. Fill hydraulic reservoir to correct level on sight glass.
Check Hydraulic Fluid Cooler
Check hydraulic fluid cooler before each use. If
dirty, clean by blowing with low pressure air. For
extensive cleaning, remove cover.
NOTICE:
•
Hydraulic reservoir can become
pressurized. OPEN SLOWLY.
•
Use SAE15W40 with additive for
hydraulic fluid in these machines.
•
Contact your Ditch Witch dealer for Power
Up additive.
- JT5 (161 pages)
- JT922 (159 pages)
- JT9 (165 pages)
- JT20 (195 pages)
- JT1220 (201 pages)
- JT2020 (203 pages)
- JT25 (203 pages)
- JT30 (245 pages)
- JT60 (218 pages)
- JT100 (243 pages)
- AT Air Hammer (11 pages)
- TK Series Manual (61 pages)
- 8500 (77 pages)
- MR90 (121 pages)
- FT5 (28 pages)
- FM5 (57 pages)
- FM13V (46 pages)
- FM25 (67 pages)
- P80 (71 pages)
- OnGrade (63 pages)
- FX20 (100 pages)
- FX25 (119 pages)
- FX30 (149 pages)
- FX50 (141 pages)
- FX60 (157 pages)
- MV800 (111 pages)
- RT30 (97 pages)
- RT45 (203 pages)
- RT55 (177 pages)
- RT100 (161 pages)
- RT115 (252 pages)
- RT120 (223 pages)
- Zahn (105 pages)
- RT80 (203 pages)
- RT115 Q (193 pages)
- RT120 Q (211 pages)
- 100SX (50 pages)
- 410SX (131 pages)
- SK350 (77 pages)
- SK750/SK755 (81 pages)
- SK850 (107 pages)
- SK850 Footings Machine (107 pages)
- 150RT (55 pages)
- 250RT (49 pages)