Manual
Service - 171
Startup/10 Hour
CMW
Check Hydraulic Fluid Level
Check hydraulic fluid level before startup and
every 10 hours of operation. Maintain fluid level
at halfway point on sight glass (2), when engine
is off and fluid is cool. Refill with THF at
hydraulic fluid fill (1).
Check Fluid Pump Oil Level
Check fluid pump oil level at fill plug (1) before
startup and every 10 hours of operation.
Maintain fluid level at fill plug. Add NDO oil at fill
plug (1) as needed.
IMPORTANT: If hydraulic system must be
opened for repair, install new filter (p/n 153-
791) for first 50 hours of operation. If this
filter becomes plugged in fewer than 20
hours, replace with clean filter. After 50 hours
of normal operation, replace with clean filter
(p/n 153-792).
- JT5 (161 pages)
- JT922 (159 pages)
- JT9 (165 pages)
- JT20 (195 pages)
- JT2020 (203 pages)
- JT25 (203 pages)
- JT30 (245 pages)
- JT60 (218 pages)
- JT100 (243 pages)
- AT Air Hammer (11 pages)
- TK Series Manual (61 pages)
- 8500 (77 pages)
- MR90 (121 pages)
- FT5 (28 pages)
- FM5 (57 pages)
- FM13V (46 pages)
- FM25 (67 pages)
- P80 (71 pages)
- OnGrade (63 pages)
- FX20 (100 pages)
- FX25 (119 pages)
- FX30 (149 pages)
- FX50 (141 pages)
- FX60 (157 pages)
- MV800 (111 pages)
- RT Line (115 pages)
- RT30 (97 pages)
- RT45 (203 pages)
- RT55 (177 pages)
- RT100 (161 pages)
- RT115 (252 pages)
- RT120 (223 pages)
- Zahn (105 pages)
- RT80 (203 pages)
- RT115 Q (193 pages)
- RT120 Q (211 pages)
- 100SX (50 pages)
- 410SX (131 pages)
- SK350 (77 pages)
- SK750/SK755 (81 pages)
- SK850 (107 pages)
- SK850 Footings Machine (107 pages)
- 150RT (55 pages)
- 250RT (49 pages)