7.4 CS24D Options Summary

In addition to the Setup Wizard, options can
also be viewed and changed using the
Sensor Options screen under the Settings
menu.

Once parameters are set, they can be
downloaded to the sensor by pressing on the
OK or Apply buttons (OK also exits the
screen). Pressing Cancel will exit with
changing sensor settings.

The chart below shows the configuration
parameters for the CS24D.

Configuration Parameter

Range

Default Setting

Sort Mode

Sets sorting algorithm

Closest Color,
Closest Match,
Unique Match

Closest Match

Error Limit

Sets error threshold limit for match

0 to 65,535

5,000

Average

Sets number of readings to be
averaged by sensor (1ms/avg)

1 to 4096

64

Stretch
Outputs (1)

Sets minimum output on-time when
a match condition is detected

0 to 65,535 ms

0

See Optimizing Section for more information on the parameters listed below

Optimization

Sets sorting algorithm

Color Only,
Color plus Intensity,
Optimized

Color plus Intensity

Weighting
Factors

Sets Weighting Factors used to
optimize sorting performance

(4) X 0 to

3

Red=1.0, Green=0.6,
Blue=1.6, Intensity=0.8

Notes:
1. When both Hold Input and Stretch Output are used, outputs will remain ON for the longer of the
Hold time or the Stretch time. (See section 4.2 for Hold Input information).
2. Sensor is always in Run mode, except:

a) when in Teach mode (Teach Mode input ON or Teach selected via ColorSense program, or
b) when operation temporarily suspended during startup or when parameters are being

downloaded and sensor is saving them to FLASH memory.