Logging – DaySequerra iLC2ST User Manual
Page 32
32
iLC2ST User Manual
Logging
Stereo Unit (A and B)
Loudness measure that is used for the stereo inputs.
Stereo Target (A and B)
Target value set for the AUX inputs.
Stereo Short Avg. (A and B)
Short combined average for the AUX inputs.
Stereo Peak (A and B)
Combined peak value of the AUX inputs.
ST-L Short Avg. (A and B)
Short average of the AUX Left input
ST-R Short Avg. (A and B)
Short average of the AUX Right input
Device Faults (A and B)
Any faults reported by the unit. Refer to the error
code table.
Data-logging Field Legend
Error Codes
After the appropriate options have been set, press the APPLY button to save those settings and
begin communications with the iLCST. The program icon should change from red to green after
communication has been established with the unit, and the iLC2ST unit will illuminate the LOGGING
LED. Switch back to the Surround tab to view the program in operation. If a setting has been
changed in error, press CANCEL to revert all settings to their previously saved state.
0
No Faults
1:x
AES Lock Error
2:x
CRC Error
3:x
Validity Error
4:x
Bi-Phase Error
5:x
No Parity Error
6
No Clock Error
7
DSP Over Utilized
1
Left / Right
Channel Code (for X)