iLC2ST User Manual

Rack Mount Installation


The ILC2ST chassis has four rack mounting holes and has been designed to fit in a standard 1RU
space. Plastic ‘finishing’ washers are recommended to protect the painted surface around the mounting
holes. Locate the air vents on each side of the unit, and be sure to keep them clear so the unit may
have adequate ventilation.


Power Connection


The AC power cable supplied with ILC2ST must be connected from the IEC320 power entry module to
an AC mains outlet with a functional earth ground connection. For protection against electric shock and
electro-magnetic interference, do not plug the power cable into a ground-lifting adapter or remove the
cable’s grounding pin. If in doubt, please consult a qualified electrician.

ILC2ST is designed with reliability in mind and contains two auto-switching power supplies. Please
connect ILC2ST to an uninterruptible power supply (UPS) to protect against power surges and low-
voltage conditions. For maximum redundancy, connect each power supply to a separate UPS on
different power circuits. ILC2ST may be combined with other devices on the output of the UPS as long
as the total load is within the UPS’ capacity. Consult your UPS manual for details.

ILC2ST will automatically power up when AC power is applied. If AC line power is lost or momentarily
interrupted, ILC2ST will revert to its previous state when the power is restored. Hard- bypass relays will
pass through audio directly to the outputs when the unit is unpowered. However, audio cannot be de-
embedded from the HD/SDI input and bypassed to the AES outputs while the unit is unpowered.

Front Panel Controls and Indicators


Status Indicators

Alarms - Red LED indicator illuminates when ILC2ST has an alarm notification.

Audio - Green LED indicator illuminates when a valid signal is present.

Network - Blue LED indicator illuminates when ILC2ST has a successful network connection.

Logging
- Green LED indicator illuminates when the ILC2ST logging is enabled on the Remote
Dashboard.