User's Guide 49

COMMAND QUICK REFERENCE

This section lists all software commands of the printer. For more information please refer to
the Programmer’s Manual.

Command Set for PPLA

The following commands are for Printer Programming Language A.

Note: In this quick reference all variable data is represented in Italics.

System Setting Commands

These commands will cause the related parameters to be saved in the non-volatile memory,
E2PROM. The parameters will be stored unless they are changed by another command,
or reset from the panel.

Command

Description

Parameter

Factory default

KI4n

Media empty check

n : ‘0’ - disable,

‘1’ - enable.

Enabled

KI7n

Set ribbon mode

n : ‘0’ – DT,

‘1’ – TT.

TT with ribbon

(for FM4402)

KI8n

Set baud rate

n : ‘0’ – 9600,

‘1’ – 600,
‘2’ – 2400,
‘3’ – 19200,
‘4’ – 4800,
‘5’ – 38400,
‘6’ – 1200,
‘7’ – 9600.

9600 baud.

(for FM4402)

KI;n

Control Code types

n : '0' - selects standard control

codes.

'1' - Select alternate control

codes

For FM4402

KXnnnn

Set continuous label
length

nnnn : a 4-digit number, in mm

KI

Set symbol set for ASD
smooth font set

m : ‘0’ - USASCII,
‘1’ - United Kingdom,
‘2’ - Spanish,
‘3’ - Swedish,
‘4’ - French,
‘5’ - German,
‘6’ - Italian,
‘7’ - Danish/Norwegian.

0 for USASCII