GASKET REPLACEMENT
Remove the doors from the unit. Place the doors, face down on a protective surface to ensure no
marring or scratching occurs during gasket replacement. To replace the Thermoglass
™ knitted rope
and tape gasket, first remove all of the old material and gasket cement. Use a putty knife or other
sharp instrument to assist in removal. Use caution to prevent injury when removing old material. It
is important to ensure the doorframe area is totally clean before installing the new gasket cement
and material. The gasket must fit tight against the doorframe in order to ensure a proper airtight
seal when the stove is being operated. Apply gasket cement to the gasket channel per instructions
provided with the gasket kit. Once the cement has been properly applied, install the new gasket.
Both gasket and gasket cement are available from your authorized Country Flame dealer. The
following table defines the gasket material used in the Ovation stove:
Gasket
Length Quantity Dimensions
Around glass
4.25 feet each
2
¾” wide by 1/16” thick tape
Doorframe
5 feet each
2
3/8
” rope, high density
Ash drawer
30 inches
1
½” wide by 1/8” thick tape
CLEARANCES
Table 1 is used to determine clearances for the stove installation based on whether a single or
double-wall connector is used from the appliance to the chimney.
SINGLE-WALL PIPE
DOUBLE-WALL
PIPE*
DISTANCES
OV-1700 & 2100
OV-2600
OV-3000
ALL MODELS
A. SIDEWALL TO UNIT
19” 20” 22” 14”
B. BACK WALL TO UNIT
10” 12” 12” 5”
C. CORNER TO UNIT
6” 6” 8” 2”
D. SIDEWALL TO CONNECTOR
28” 29” 31” 23”
E. BACK WALL TO CONNECTOR
13” 16.5” 16.5” 9”
F. CORNER TO CONNECTOR
16” 16.5” 19” 11.5”
TABLE 1: REQUIRED CLEARANCES
* Factory-built chimney systems should use a chimney UL Listed to 103HT or equivalent product
in the United States. For Canada, use chimney listed to ULCS629.