beautypg.com

Cleaning instructions…continued – American Energy Systems MagnuM Baby Countryside User Manual

Page 26

background image

26

CLEANING INSTRUCTIONS…continued

WARNING: DISCONNECT THE POWER CORD BEFORE CLEANING OR SERVICING THIS UNIT.
THE STOVE MUST BE TURNED OFF AND COOLED BEFORE USING THE RAKE HANDLE.

II. HEAT EXCHANGER:

This stove is designed with a built-in heat exchange tube
Rake. The ash handle is located on the front of the stove
and is moved backwards and forwards several times
to remove the buildup of ash. After cleaning, push the
rake handle in until it stops.


III. COMBUSTION BLOWER:

Over the course of the heating season dust and ash may collect on the blades of the combustion blower.
Periodically they should be inspected and vacuumed clean. The combustion blower is accessed by opening the
stove’s right side panel and then removing the inspection caps or the exhaust manifold cover (See figure below).
Never operate the stove without the inspection cap or manifold cover in place.




ASH RAKE HANDLE

Essex Model Shown, All models have a

Ash Rake in the top front grill area

The manual reset thermodisk must
be reset by pushing in on the center
button. This can be tripped when
cleaning the unit or when the unit
overheats.

EXHAUST
MANIFOLD
COVER

HOPPER

REAR EXHAUST

OUTSIDE

AIR

INLET

SIDE PANEL

CAP

INSPECTION

AUTO RESET

150 NORMALLY OPEN

COOL DOWN

HIGH TEMP SHUT OFF

AUGER THERMODISK

AUTO RESET

150 NORMALLY OPEN

PROOF OF FIRE THERMODISK

200 MANUAL RESET

110 deg.

110

Optional Location