Table 1-5: Trigger Bus Settings
1.5.7
System Reference Clock
The PXIS-2719A supplies a PXI 10MHz system reference clock
(PXI_CLK10) to each peripheral slot for inter-module synchroniza-
tion. An independent buffer (having source impedance matched to
the backplane and a skew of less than 1 ns between slots) drives
the clock signal generated from a high-precision oscillator to each
peripheral slot.
This common reference clock signal can synchronize multiple
modules in a PXI chassis. The 10 MHz reference clock is impor-
tant to the PXI specification for inter-module synchronization. PXI
modules which have phase-locker loop circuit can lock the 10
MHz reference clock to generate an in-phase timebase.
The PXIS-2719A PXI chassis automatically selects the source of
the 10 MHz reference clock from
X
Built-in accurate 10 MHz oscillator
X
External 10 MHz clock through a BNC connector
X
PXI_CLK10_IN pin on the star trigger slot
P2
P3
P4
P5
Configuration Description
x
x
x
x
N/A
N/A
OFF
OFF
x
x
All Segments
Isolated
All Segments Isolated
ON
ON
ON
ON
1 → 2 → 3
Segment 1 to 2 & 3
ON
OFF
ON
OFF
1 → 2
Segment 1 to 2
ON
OFF
OFF
OFF
1 ← 2
Segment 2 to 1
OFF
ON
OFF
ON
2 → 3
Segment 2 to 3
OFF
ON
OFF
OFF
2 ← 3
Segment 3 to 2
ON
ON
OFF
OFF
1 ← 2 ← 3
Segment 3 to 1 & 2
ON
ON
OFF
ON
1 ← 2 → 3
Segment 2 to 1 & 3