Appendix B Timer/Counter Operation

Control Byte
Before loading or reading any of these individual counters, the control byte
(BASE+3) must be loaded first. The format of the control byte is:

Bit

7

6

5

4

3

2

1

0

SC1

SC0

RL1

RL0

M2 M1 M0

BCD

• SC1 & SC0 - Select Counter ( Bit7 & Bit 6)

SC1 SC0 COUNTER

0

0

Select Counter 0

0

1

Select Counter 1

1

0

Select Counter 2

1 1 ILLEGAL

• RL1 & RL0 - Select Read/Load operation ( Bit 5 & Bit 4)

RL1 RL0 OPERATION
0

0

COUNTER LATCH FOR STABLE READ

0 1 READ/LOAD

LSB

ONLY

1 0 READ/LOAD

MSB

ONLY

1

1

READ/LOAD LSB FIRST, THEN MSB

• M2, M1 & M0 - Select Operating Mode ( Bit 3, Bit 2, & Bit 1)

M2 M1 M0

MODE

0 0 0 0
0 0 1 1
x 1 0 2
x 1 1 3
1 0 0 4
1 0 1 5

• BCD - Select Binary/BCD Counting ( Bit 0)

0

16-BITS BINARY COUNTER

1

BINARY CODED DECIMAL (BCD) COUNTER (4
DIGITAL)

Note

The count of the binary counter is from 0 up to
65,535 and the count of the BCD counter is from
0 up to 9,999