• Signal Connections & Applications
360,000,000 = 60000 x 6000
Therefore, ‘user configurable cascaded counters’ can be used
to solve this problem. The counter #1 and #2 are used in this
example.
step 3: Set jumper ‘CK1’. The clock source is internal ‘CLOCK2’ and it
is set as 100 KHz in default. Then set jumper ‘CK2’ and the
clock source is coming for the output of the ‘Last channel (#1)‘.
step 4: Skip these steps.
step 5: Write and verify the control program for counter #1.
step 6: Skip these steps.
step 7: The gate source of the two counters is enable always. Note the
jumper ‘G1’ and ‘G2’ should be removed and no external gate
signals are used.
step 8: Connect the counter #2 output to external device. The following
block diagram illustrates the application
step
9: Write and verify the control program. Please refer the
‘DEMO2.C’ source code.
100 K Hz
COUT1
Counter #1
8254 Chip #1
C
G
O
'H'
Jumper
CK1
Jumper
CLOCK2
COUT2
Counter #2
8254 Chip #1
C
G
O
'H'
Jumper
CK2
Figure 4.3 Example of frequency generator (2)