C/C++ Libraries • 45

5.7 _8554_Read_Status

@ Description

User can directly read current counter status with this function.

@ Syntax

C/C++ (DOS)

U16 _8554_Read_Status (U16 cardNo, U16 cntNo, U16 * cntrVal,

U16 *status)

C/C++ (Windows 95)

U16 W_8554_ Read_Status (U16 cardNo, U16 cntNo, U16 * cntrVal,

U16 *status)

Visual Basic (Windows 95)

W_8554_Read_Status (ByVal cardNo As Integer, ByVal cntNo

As Integer, cntrVal As Integer, status As Integer) As
Integer

@ Arguments

cardNo:

card number to be selected

cntNo:

Counter/Timer number. This value must be
between 1 and 12.

cntrVal:

Counter value read back from counter

status:

current status read back from counter, refer to
8254’s datasheet for more information

@ Return Value

ERR_NoError, ERR_BoardNoInit

ERR_InvalidCounterNo:

if cntNo is not in the range of 1 ~ 12